3,025 research outputs found
Graphene: A Context-Preserving Open Information Extraction System
We introduce Graphene, an Open IE system whose goal is to generate accurate,
meaningful and complete propositions that may facilitate a variety of
downstream semantic applications. For this purpose, we transform syntactically
complex input sentences into clean, compact structures in the form of core
facts and accompanying contexts, while identifying the rhetorical relations
that hold between them in order to maintain their semantic relationship. In
that way, we preserve the context of the relational tuples extracted from a
source sentence, generating a novel lightweight semantic representation for
Open IE that enhances the expressiveness of the extracted propositions.Comment: 27th International Conference on Computational Linguistics (COLING
2018
Graphene: Semantically-Linked Propositions in Open Information Extraction
We present an Open Information Extraction (IE) approach that uses a
two-layered transformation stage consisting of a clausal disembedding layer and
a phrasal disembedding layer, together with rhetorical relation identification.
In that way, we convert sentences that present a complex linguistic structure
into simplified, syntactically sound sentences, from which we can extract
propositions that are represented in a two-layered hierarchy in the form of
core relational tuples and accompanying contextual information which are
semantically linked via rhetorical relations. In a comparative evaluation, we
demonstrate that our reference implementation Graphene outperforms
state-of-the-art Open IE systems in the construction of correct n-ary
predicate-argument structures. Moreover, we show that existing Open IE
approaches can benefit from the transformation process of our framework.Comment: 27th International Conference on Computational Linguistics (COLING
2018
Ressonância Magnética Multiparamétrica na deteção do carcinoma da próstata
Trabalho final de mestrado integrado em Medicina, apresentado à Faculdade de Medicina da Universidade de Coimbra.Introdução
O carcinoma da próstata é o segundo carcinoma mais frequente no homem. O diagnóstico é
feito com base em análise histopatológica obtida em biopsia dirigida por ecografia transrectal.
A baixa taxa de deteção da biopsia sistemática obriga à repetição da técnica aumentando os
efeitos secundários deste procedimento invasivo. A Ressonância Magnética Multiparamétrica
está indicada no estadiamento do carcinoma da próstata, e tem vindo a mostrar bons
resultados na deteção e orientação da biopsia. Contudo, a variabilidade destes resultados têm
impedido a sua indicação clara no diagnóstico. Com a criação do score PIRADS (Prostate
Imaging Reporting and Data System) pela ESUR (European Society of Urogenital Radiology)
foi dado um passo no sentido da normalização da técnica que, ainda assim, deve ser
confirmada e aperfeiçoada.
Objetivo
Avaliar a utilidade dos diversos parâmetros da Ressonância Magnética, isoladamente e em
conjunto, na deteção de carcinoma prostático em doentes com suspeita clinica e biopsias
negativas.
Materiais e Métodos
No estudo foram incluídos 34 indivíduos com suspeita de carcinoma prostático e biopsias
prévias negativas. Foram sujeitos a Ressonância Magnética Multiparamétrica e nova biopsia
foi realizada posteriormente. Os doentes com baixa probabilidade de carcinoma e que não
realizaram biopsia foram seguidos prospectivamente. Os parâmetros avaliados incluem a
ponderação T2, ponderação em difusão, estudo dinâmico após contraste e espectroscopia. Os exames foram obtidos por um equipamento Magnetom Trio Tim, 3 Tesla, Siemens. Foi usada
antena de coluna com 12 canais e “body phased array” com 16 canais. As imagens foram
classificadas com base no score PIRADS. Com o objetivo de análise os scores foram
dicotomizados: scores 4 e 5 foram considerados como resultado positivo e scores 1, 2 e 3
foram considerados negativos. Foi calculada a sensibilidade, especificidade, acuidade, valor
preditivo positivo e negativo. Foi calculada a área sob a curva (AUC) para cada parâmetro,
para a combinação de parâmetros excluindo a espectroscopia e para o resultado global da
Ressonância Magnética. Para cada grau Gleason encontrado calculou-se a média de scores em
cada parâmetro e as médias foram comparadas.
Resultados
Dos 34 doentes sujeitos a estudo foram identificados 8 carcinomas prostáticos após resultado
positivo na Ressonância Magnética. Para o resultado global a sensibilidade foi de 88.89%, a
especificidade de 80%, o valor preditivo negativo de 95.23%, o valor preditivo positivo de
61.54% e a acuidade de 82.35%.
A AUC global foi de 0.887 (p=0.001). A espectroscopia foi o parâmetro que individualmente
apresentou uma AUC mais elevada com um valor de 0.880 (p=0.006) seguida da ponderação
T2 com 0.838 (p=0.015), ponderação em difusão com 0.741 (p=0.083) e por ultimo o estudo
com contraste com 0.713 (p=0.125). A combinação da ponderação T2, difusão e estudo com
contraste apresentou uma AUC de 0.856 (p=0.002).
Na comparação de médias dos scores em cada grau Gleason não se encontrou diferenças
estatisticamente significativas.
4
Conclusão
A Ressonância Magnética Multiparamétrica de 3T com ponderação em T2, difusão, contraste
dinâmico e espectroscopia é útil na deteção de carcinoma e na orientação da biopsia
prostática. Estes resultados são assim mais um contributo no esclarecimento do potencial
papel deste exame imagiológico no diagnóstico do carcinoma prostático.Introduction
Prostate cancer is the second most frequent cancer in men. Diagnosis is made based on
histophatologic analysis, obtained by transrectal ultrasound-guided prostate biopsy. The low
rate of detection found in the systematic biopsy forces the repetition of the procedure,
increasing the adverse effects of this invasive technique. Multiparametric Magnetic
Resonance is indicated in prostate cancer staging, and has been showing good results in its
detection and in guided biopsy. However, variable results have hampered a clear indication in
diagnosis. With the creation of PIRADS (Prostate Imaging Reporting and Data System) score
by ESUR (European Society of Urogenital Radiology), it was given a step forward in
achieving the technique normalization, nevertheless, it should be confirmed and improved.
Objectives
The aim is to evaluate the utility of the several parameters included in Magnetic Resonance,
singly and together, in detection of prostate cancer in patients with both clinical suspicion and
negative biopsies.
Methods
In this study there were 34 patients with suspected prostate cancer and negative preview
biopsies. They were subjected to Multiparametric Magnetic Resonance and a new biopsy was
taken later. The patients with low probability of prostate cancer and whom, because of that,
didn’t realize biopsy, were followed and analyzed prospectively. The combination of
parameters includes T2-weighted images, diffusion-weighted, dynamic contrast-enhanced
imaging and spectroscopy. The technique was made with an equipment Magneton Trio Tim, 3 Tesla, Siemens. It was used spine coil with 12 channels and body phased array with 16
channels. Resulting images were classified based on PIRADS score. For analysis, results were
dichotomized: 4 and 5 were considered a positive result, and 1, 2 and 3 were considered as a
negative result. It were determined sensitivity, specificity, accuracy, positive predictive value
and negative predictive value. ROC curve was made and the area under the curve (AUC) was
determinated for each parameter, for the parameters combination without spectroscopy, and
for the global result of Magnetic Resonance.
For each Gleason grade that was found, range scores in each parameter were calculated and
the ranges were compared.
Results
Within these 34 patients there have been identified 8 prostate cancers after a positive result in
Magnetic Resonance. For the global result, sensitivity was 88.89%, specificity 80%, negative
predictive value 95.23%, positive predictive value 61.54% and accuracy of 82.35%.
Global AUC was 0.887 (p=0.001). Spectroscopy was the parameter with the highest AUC
with 0.880 (p=0.006) followed by T2-weighted with 0.838 (p=0.015), diffusion-weighted
with 0.741 (p=0.083) and for last dynamic contrast-enhanced imaging 0.713 (p=0.125). The
combination of T2-weighted images, diffusion-weighted and dynamic contrast-enhanced
imaging revealed an AUC of 0.856 (p=0.002). The comparison of the ranges in each Gleason
score didn’t show any statistically significant difference.
Conclusion
3T Multiparametric Magnetic Resonance with inclusion of T2-weighted images, diffusionweighted,
dynamic contrast-enhanced imaging and spectroscopy is a useful technique in
7
detection of cancer and guiding prostate biopsy. These results give a strong contribution in
clarifying the potential rule of this imaging exam in the diagnosis of prostate cancer
ReLiPh: rehabilitation for lower limb with phantom pain
O membro fantasma ou sensação fantasma, ao longo dos anos, têm se destacado por
ser originada de diferentes causas. Pesquisas e estudos mostram que, após uma
amputação, na maioria dos casos, experienciam a sensação de membro fantasma e
em muitos desses casos dolorosos.
A presente tese baseia-se em uma pequena parte deste amplo tópico. Baseada na
terapia de espelho usada na reabilitação e tratamento da dor fantasma. Ao longo do
projeto, nós estudamos quais são os componentes mais relevantes para a
reorganização/reestruturação, a fim de eliminar os sintomas negativos e futuros
distúrbios/perturbações. Associada na relação do cérebro com o corpo, ou seja, as
imagens formadas pelo cérebro em relação ao corpo físico desempenhando um papel
crucial na relação do membro fantasma e da dor no membro fantasma, bem como no
processo de cura e tratamento através de exercícios e no relacionamento da imagem
que o cérebro tem do corpo físico.
Esta dissertação tem como objetivo na construção de uma nova abordagem
tecnológica, baseando-se nos princípios e critérios utilizados na terapia de espelho.
A metodologia assenta na criação de um ambiente de realidade virtual controlado
por um dispositivo que captura a atividade muscular em tempo real. Implementado
num jogo baseado em movimentos/exercícios simples e naturais, sem uso de força
ou esforço.
Os elevados resultados verificados e testados, em indivíduos saudáveis e em um
estudo de caso, na redução da dor fantasma, gerando um interesse e motivação, além
de um melhor senso de presença e foco durante o seu uso. Concluindo, o projeto
abre novas direções futuras de como novas abordagens tecnológicas podem ser
usados nas pesquisas médicas na área do membro e na dor fantasma, em ambientes
controlados e contextualizados. Melhorando a eficácia e eficiência, garantindo uma
maior flexibilidade nos diferentes casos de amputação.The phantom limb or phantom sensation, over the years, has stood out being
originated from different causes. Research and studies show that after an amputation,
in most cases, they experience the sensation of a phantom limb and in many of those
painful feelings.
This thesis is based on a small part of this wide topic. Based on the mirror therapy
used in rehabilitation and treatment for phantom pain. Throughout the project, we
study what are the most relevant components to reorganization/restructuring in order
to eliminate negative symptoms and future disturbances. Moreover it is established
in the relationship of the brain with the body, that the images formed by the brain
in relation to the physical body play a crucial role in the relationship with the
phantom limb and phantom limb pain, as well as in the process of healing and
treatment throughout exercises and the relationship of the image that the brain has
to the physical body.
This dissertation aims to build a new technological approach, based on the principles
and criteria used in mirror therapy. The methodology is based on the creation of a
virtual reality environment controlled by a device which captures the muscle activity
in real time. Implemented in a game based on natural and simple effortless exercises
without the use of strength.
The high results verified and tested, in healthy subjects and in a case study, to reduce
phantom pain, generating an interest and motivation, as well as a better sense of
presence and focus during its use. In conclusion, the project opens up new future
directions of how new technological approaches can be used in medical research in
the field of phantom limbs and in phantom pain, in a controlled and contextualized
environments and/or movements. Improving effectiveness and efficiency ensuring
greater flexibility in different cases of amputation
- …